Fire Emergency Diesel Engine Pump

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (29)
  • Fire Emergency Diesel Engine Pump
  • Fire Emergency Diesel Engine Pump
  • Fire Emergency Diesel Engine Pump
  • Fire Emergency Diesel Engine Pump
  • Fire Emergency Diesel Engine Pump
  • Fire Emergency Diesel Engine Pump
Find Similar Products
  • Overview
  • Short description
  • General function
  • Function of control
  • Select water pump
Overview

Basic Info.

Model NO.
BD
Control Function
Self-Starting Function
Function
Automatic Preheating Function
Application Field
Factories, Mines, Oilfields, etc.
Power Supply
DC24V
Transport Package
Wooden Case or as Your Require
Specification
Metal
Trademark
BODA
Origin
Shijiazhuang
HS Code
8413701090
Production Capacity
200pieces/Year

Product Description

Short description

 

X(Y)CBZG model series fire protection and emergency diesel engine pump unit auto water supply machine currently has been widely applied in sectors such as plants mines oil fields harbors steels and chemicals etc. majorly for drainage of industrial mines agricultural irrigation flood fighting pollution emission emergency cooling of steel plants and emergency water supply for civil fire protection. It replaces traditional way that use diesel engine power generator unit to start water pump and as emergency backup power for civil and fire protectio it particularly is adaptable for unusual situation of water supply and drainage such as no alternating current power supply and power insufficient.

General function

 

1) A verticle control panel that uses PLC DC programmable controller as the core of master control, could mannualy or automatically control the water pump's diesel engine unit via cables.

2) The diesel engine is equipped with sensor for detecting velocity, temperature of water and oil, and oil pressure, used for inspection over the operational parameter of diesel engines and warning the signal source of protection.

3) The control panel has diesel engine hour totalizer, and indicates water and oil temperature, oil pressure, velocity, current (charge), and warning of high/low temperature of water and oil, overspeed, and failure to start for three times. Besides, it installs DC24V electrical source, indicator lights of pre-lubricant, pre-heating, charge (civil power charge),diesel engine start, engine unit operational and shutdown, etc., and electrical source key switch, and button/switch mannually or automatically controlled; it also could set button/switch of municiple warning, silencing and reset.
 

Function of control

 

1) Self-starting function
When the mannual/auto switch on the control panel is on auto mode, mannual operation would not work. Once the control panel received start order, it would proceed self-starting programme. Before the first start, pre-lubricant pump start working for 10-20 seconds, then start diesel engine (for about 5-8 seconds); if the start fail, wait for 5-10 seconds beofre re-start; repeat the trial for 3 times; if it ends in failure after trial start for three times, output the signal of start failure. Once it starts sucessfully, idle running for 5-10 seconds then automatically rise to the specified velocity, meanwhile send signal and switch on the clutch within 20 seconds to start for normal operation.

2) Auto pre-heating function
The engine unit could add pre-heating system device in order to ensure a perfect start of the diesel engine when the environmental temperature in the engine room lower than 5 centigrade

3) Pre-lubricating system
When start a high power multi-cylinder diesel engine with low ambient temperature, a bigger start resistance will occur, therefore, a pre-lubricating pump should be added to impose an pre-lubricating before start running the diesel engine.

4) Auto-charging function
For the purpose of a perfect start to diesel engine even in case of an interruption of AC power supply, we can set auto-charging device in the control cabinet which through AC220C civil power to charge the storage battery, besides charing by power generator to charging generator when diesel engine is running.
 

5) Auto-stop function
When the auto control panel receives a warning stop signal, the central control room stop signal or emergency stop signal, the engine unit will proceed shutdown procedure.

6) Manual start function
Before formally running the machine, manually push each button to inspect each function such as pre-lubricating, start, speed-raising, speed reduction, shutdown and clutch of switching on/off power; when everything is running on track, the automatic procedure could proceed.

7) Protective warning function
When the water or oil temperature overheat (above 0.17mpu), or malfunction occurs such as overspeed, and disconnection of velocity sensor, the control cabinet would give warning signals.
 

Select water pump
  Pump Water configuration Specification Single engine multi-stage Suggested model
  Large volume Q=540m3/n below multi-stage D  Model
  Big lift H=697m below multi-stage D  Model
  Super power 1120Km below multi-stage D  Model
  Small volume Q=460mVn below Single-stage IS  Model
  Small lift H=145m below Single-stage IS  Model
  Low power N=llOKm below Single-stage IS  Model
  Super volume Q=6460m3/n below Single-stage SH, 0S  Model
  Small lift H=140m below Single-stage SH, 0S  Model
  High power N=960Km below Single-stage SH, 0S  Model
  Small volume Q=45m3/n below Multi-stage DC, DG  Model
  Big lift H=301m below Multi-stage DC, DG  Model
  Low power N=75Km below Multi-stage DC, DG  Model
  Mediate volume Q=288m3/n below Multi-stage DAi  Model
  Mediate lift H=333m below Multi-stage DAi  Model
  Mediate power N=200Km below Multi-stage DAi  Model
Fire Emergency Diesel Engine PumpFire Emergency Diesel Engine PumpFire Emergency Diesel Engine PumpFire Emergency Diesel Engine PumpFire Emergency Diesel Engine Pump