• Jywq Series Automatic Mixing Sewage Pump
  • Jywq Series Automatic Mixing Sewage Pump
  • Jywq Series Automatic Mixing Sewage Pump
  • Jywq Series Automatic Mixing Sewage Pump
  • Jywq Series Automatic Mixing Sewage Pump
  • Jywq Series Automatic Mixing Sewage Pump

Jywq Series Automatic Mixing Sewage Pump

After-sales Service: 1 Years
Warranty: 1 Years
Max.Head: 30-50m
Max.Capacity: 50-100 L/min
Driving Type: Motor
Impeller Number: Single-Stage Pump
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2014

Suppliers with verified business licenses

Hebei, China
to see all verified strength labels (29)

Basic Info.

Model NO.
BODA-107
Working Pressure
High Pressure Pump
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Mounting Height
Suction Centrifugal
Impeller
Open or Closed
Usage
Pumps
Size
8 Inches
OEM
Yes
Factory
Yes
After Sale Service
Yes
Application
Metallurgical, Mining, Coal, Power, Building Mater
Usage 1
Mining Industry
Structure
Single-Stage Pump
Theory
Sewage Pump
Material
Ba05. Ba07, Ba49 High Chrome Alloy
Seal Form
Mechanical Seal, Expeller Seal or Packing Seal
Transport Package
Wooden Case
Specification
Electromagnetic Pump
Trademark
Boda
Origin
Shijiazhuang
HS Code
8413709990
Production Capacity
500 Sets/ Month

Product Description

Jywq Series Automatic Mixing Sewage PumpJywq Series Automatic Mixing Sewage Pump
JYWQ automatic mixing sewage pump overview

      JYWQ, JBWQ, JPWO series automatic mixing sewage pump is based on the ordinary sewage pump. The automatic stirring device is used. The device rotates with the motor shaft to generate a strong stirring force. The sediment in the sewage pool is stirred into suspended matter and inhaled. The pump discharges, improves the pump's anti-blocking and sewage discharge capacity, and completes the drainage, cleaning, desilting and saving operation costs at one time. It is an environmentally friendly product with obvious advancement and usability. Note: JYWQ and JBWQ are ordinary type automatic mixing and discharging sewage pumps; JPWQ is a stainless steel jacket internal circulation cooling system to automatically mix the sewage pump.

Main features of JYWQ automatic mixing sewage pump

1. When the sewage pump is automatically stirred, the bottom sediment of the tank is automatically stirred to completely prevent the dirt from accumulating, without manual cleaning;

2. Unique impeller design with the function of chopping and tearing fibrous materials and debris;

3. The external circulation cooling system is adopted to make the sewage pump run at a low water level, reduce the starting frequency of the motor, and prolong the life of the motor;

4. National standard atlas recommended products;

5. Shanghai high-tech achievements transformation products.

JYWQ automatic mixing of sewage pump model meaning

Example: 80JYWQ50-10-1600-3

80-row exit diameter (mm)

JYWQ-automatic mixing and sewage pump

50-flow (m3/h) 10-head (m) 1600-stirring range (mm) 3-motor power (KW)

JYWQ automatic mixing and discharging sewage pump main use

1. Discharge of heavily polluted wastewater from factories and businesses.

2. Drainage system of urban sewage treatment plants, hospitals and hotels.

3. Sewage drainage station in residential area.

5. Municipal engineering, construction sites.

6. Exploration, mining, and power plants are equipped with attached machines.

7. Rural biogas digesters, farmland irrigation, and river pond dredging.

JYWQ automatic mixing and draining pump use precautions

(1) Before operation, use a megger to check the insulation resistance of the stator winding of the motor to ground, which is not less than 50 megohms.

(2) Check the cable for damage or breakage. If damage occurs, it must be replaced in time to avoid leakage; the cable cross section should match the current.

(3) The electric pump must not be started when the voltage exceeds ±10% of the rated voltage.

(4) In order to ensure the safety of use, the grounding wire in the four-core cable must be reliably grounded to prevent electric shock.

(5) When the electric pump is submerged into the water, it should be lifted vertically, and it is not allowed to land horizontally, and it should not fall into the sludge. When the battery is stopped, the electric pump should be lifted and cleaned, placed in a dry place, and protected from freezing.

(6) It is forbidden to use the cable as a hoisting rope.

(7) Check the rotor running direction and turn it clockwise from the top to the bottom.

(8) Outdoor switches or terminals should be protected from rain and moisture. Do not touch the switch when wet or barefoot to prevent electric shock.

(9) When moving the electric pump, the power must be cut off. When the electric pump is running, people should not touch the water source to prevent personal accidents from leakage.

(10) It is strictly forbidden to run the phase of the motor. If the fuse is found to be blown, the cause should be checked before use. Do not arbitrarily thicken the fuse.

(11) When the pump is running, it should be managed by a special person. If abnormality is found, it should be stopped immediately to check and eliminate the fault. (refers to the case of the automatic protection cabinet at the end).

(12) After the electric pump has been operating normally under the specified working medium conditions for half a year, the oil chamber sealing condition should be checked. If the oil in the oil chamber is milky or has water precipitation, the mechanical oil and mechanical seal No. 10-20 should be replaced in time. For electric pumps used under severe working conditions, they should be inspected frequently.

(13) The user should select the appropriate flow head according to the actual working conditions to achieve good results. The parameters shown on the pump nameplate or the manual are the best working conditions. The user can choose (0.7~1.2) times better. Use within the flow, prohibit super-flow use, otherwise the flow is too large, the lift is too low and the motor is overloaded.
   

(mm)


(m3/h)


(m)


(mm)


(r/min)


(%)

 
1 JYWQ50-12-15-1200-1.5 50 12 15 1200 2900 48 CAK-50
2 JYWQ50-20-7-1200-1.1 50 20 7 1200 2900 62 CAK-50
3 JYWQ50-10-10-1200-1.1 50 10 10 1200 2900 56 CAK-50
4 JYWQ50-15-15-1200-2.2 50 15 15 1200 2900 51 CAK-50
5 JYWQ50-25-10-1200-2.2 50 25 10 1200 2900 65 CAK-50
6 JYWQ50-15-20-1200-2.2 50 15 20 1200 2900 56 CAK-50
7 JYWQ50-20-15-1200-2.2 50 20 15 1200 2900 56 CAK-50
8 JYWQ50-42-9-1200-3 50 42 9 1200 2900 56 CAK-50
9 JYWQ50-17-25-1200-3 50 17 25 1200 2900 56 CAK-50
10 JYWQ50-25-22-1200-4 50 25 22 1200 2900 62 CAK-50
11 JYWQ50-40-15-1400-4 50 40 15 1400 2900 70 CAK-50
12 JYWQ50-25-32-1600-5.5 50 25 32 1600 2900 52 CAK-50
13 JYWQ50-40-30-1600-7.5 50 40 30 1600 2900 68 CAK-50
14 JYWQ65-25-15-1400-3 65 25 15 1400 2900 65 CAK-65
15 JYWQ65-37-13-1400-3 65 37 13 1400 2900 62 CAK-65
16 JYWQ65-25-28-1400-4 65 25 28 1400 2900 60 CAK-65
17 JYWQ80-40-7-1600-2.2 80 40 7 1600 2900 54 CAK-80
18 JYWQ80-29-8-1600-2.2 80 29 8 1600 2900 54 CAK-80
19 JYWQ80-43-13-1600-4 80 43 13 1600 2900 63 CAK-80
20 JYWQ80-50-10-1600-3 80 50 10 1600 1450 76 CAK-80
21 JYWQ80-40-15-1600-4 80 40 15 1600 2900 70 CAK-80
22 JYWQ80-60-13-1600-4 80 60 13 1600 2900 70 CAK-80
23 JYWQ80-35-25-1600-5.5 80 35 25 1600 2900 64 CAK-80
24 JYWQ80-50-25-1600-7.5 80 50 25 1600 2900 70 CAK-80
25 JYWQ80-50-30-1600-7.5 80 50 30 1600 2900 70 CAK-80
26 JYWQ100-80-9-2000-4 100 80 9 2000 1450 62 CAK-100
27 JYWQ100-110-10-2000-5.5 100 110 10 2000 1450 71 CAK-100
28 JYWQ100-70-15-2000-5.5 100 70 15 2000 1450 71 CAK-100
29 JYWQ100-100-15-2000-7.5 100 100 15 2000 1450 73 CAK-100
30 JYWQ100-80-20-2000-7.5 100 70 20 2000 2900 71 CAK-100
31 JYWQ100-50-35-2000-11 100 100 35 2000 2900 68 CAK-100
32 JYWQ100-70-22-2000-7.5 100 80 22 2000 2900 70 CAK-100
33 JYWQ100-100-22-2000-15 100 150 22 2000 1450 61 CAK-100
34 JYWQ100-80-30-2000-15 100 210 30 2000 1450 67 CAK-100
35 JYWQ150-150-10-2000-7.5 150 250 10 2000 1450 75 CAK-150
36 JYWQ150-210-7-2500-7.5 150 150 7 2500 1450 78 CAK-150
37 JYWQ150-250-6-2500-7.5 150 200 6 2500 1450 79 CAK-150
38 JYWQ150-150-15-2500-11 150 65 15 2500 1450 79 CAK-150
39 JYWQ150-200-10-2500-15 150 180 10 2500 1450 73 CAK-150
40 JYWQ150-65-40-3200-18.5 150 150 40 3200 1450 58 CAK-150
41 JYWQ150-180-22-2600-18.5 150 110 22 2600 1450 75 CAK-150
42 JYWQ150-150-26-2600-18.5 150 300 26 2600 1450 72 CAK-150
43 JYWQ150-110-30-2600-18.5 150 130 30 2600 1450 72 CAK-150
44 JYWQ150-300-15-2600-22 150 100 15 2600 1450 76 CAK-150
45 JYWQ150-130-30-2600-22 150 300 30 2600 1450 70 CAK-150
46 JYWQ150-100-40-3000-30 150 250 40 3000 1450 64 CAK-150
47 JYWQ200-300-7-3000-11 200 300 7 3000 1450 75 CAK-200
48 JYWQ200-250-11-3000-15 200 250 11 3000 1450 72 CAK-200
49 JYWQ200-300-10-3000-15 200 300 10 3000 1450 75 CAK-200
50 JYWQ200-250-15-3000-18.5 200 250 15 3000 1450 72 CAK-200
51 JYWQ200-400-10-3000-22 200 400 10 3000 1450 75 CAK-200
52 JYWQ200-200-20-3000-22 200 200 20 3000 1450 73 CAK-200
53 JYWQ200-250-22-3000-30 200 250 22 3000 1450 73 CAK-200
54 JYWQ250-600-7-3000-22 250 600 7 3000 1450 78 CAK-250
55 JYWQ250-600-9-3000-30 250 600 9 3000 1450 78 CAK-250
Jywq Series Automatic Mixing Sewage PumpJywq Series Automatic Mixing Sewage PumpJywq Series Automatic Mixing Sewage Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now